Maritime Propulsion Power the maritime industry

Noris Group System / Package

N3000-SAP Engine Safety System

Compact engine safety system monitoring combustion engine operating parameters and triggering emergency shutdown; digital signal processing, wire-break monitoring, IP65 stainless housing, class approved.

Description

The N3000-SAP safety system electrically monitors the basic operating parameters of a combustion engine and is the central unit for triggering an emergency shutdown to prevent damage. Its compact, robust design makes it suitable for installation on ships directly on the engine. Signal processing is purely digital, combined with fast, crystal-accurate speed acquisition.

Key features

  • Large number of preprogrammed engine types
  • All inputs monitored for wire break and short circuit
  • Plug-in connections for easy installation

Inputs and outputs

  • 4 manual emergency stop inputs; 5 automatic stop inputs
  • 2 pick-up inputs for non-contact speed acquisition
  • 2 override inputs for automatic stop channels, assignable per class requirements
  • 1 remote reset input
  • Shutdown outputs I < 2 A @ 24 VDC; signal outputs I < 0.5 A @ 24 VDC
  • Analog outputs 4…20 mA (RL ≤ 600 Ω) and 0…10 V (IL ≤ 20 mA)

Technical data

  • Operating voltage: 18 … 73 VDC; power consumption < 10 W
  • Operating temperature: -25 … +70°C; storage -40 … +100°C
  • Protection: IP65 when installed; stainless steel housing, laminated aluminium front
  • Front panel: 250 x 140 x 4 mm; weight approx. 1.4 kg
  • Standards: IEC61000-6-2, IEC61000-6-4, IACS UR E10 Rev8

Approvals

ABS, BV, LR, NK, RINA and RMRS certificates.

Specifications

TypeSignal panel for installation in control cabinets and operating panels
Operating voltage UB18 … 73 VDC
Operating temperature-25°C … +70°C
Power Consumption< 10W ±10%
Storage Temperature-40°C … +100°C
Relative HumidityAccording to IEC60068-2-30 Db ≤ 96% @ 55°C
Vibration ResistanceAccording to IEC60068-2-6 Fc
Shock ResistanceAccording to IEC60068
Electromagnetic immunityAccording to IEC 61000-4 and IEC 60553
Electromagnetic emissionsAccording to CISPR 16-1– EMC2
Connections4 x inputs for manual emergency stop5 x inputs for automatic stop2 x pick-up inputs for non-contacting speed acquisition2 x inputs for overriding the automatic stop channels with channel assignment as per the requirements of the various classes1 x input for remote reset of the automatic stop channel
Terminal typePlug-in terminals, wire cross-section ≤ 2.5mm²
Switching Capacity of OutputsShutdown Outputs with I < 2 A @ 24 VDCSignal Outputs with I < 0.5 A @ 24 VDC
Analog Out 4 … 20 mALoad Resistance RL ≤ 600 Ω
Analog Out 0 … 10 VLoad Current IL ≤ 20 mA
Wire-Cable monitoringFull wire break and short circuit detection
Protection ClassIP65 when installed
User interface materialLaminated aluminum
HousingStainless steel
Front panel dimensionsL: 250mm, W: 140mm, D: 4mm
WeightApprox.1.4 kg
Applied StandardsIEC61000-6-2; IEC61000-6-4; IACS UR E10 Rev8

More from Noris Group

All products of Noris Group →

Similar products