Kelvion Maintenance / Service Agreement
Service for Closed Circuit Coolers
Kelvion service for closed circuit coolers of generators and electric drives: cleaning and testing, recoiling, header recoating, retubing, repairs, condition analysis and reverse engineering.
Description
Kelvion's Service for Closed Circuit Coolers keeps generator and electric drive coolers performing, preventing the stator or drive from overheating. Deposits accumulating in the tubes can cause hot spots, cracks and leakages or damage to fins and coatings. The service includes cleaning and testing, recoiling, recoating of water headers, repairs and reverse engineering.
Service solutions
- Mechanical and chemical cleaning
- Refurbishment programme – components checked against new equipment standards; cleaning, retubing or part replacement depending on damage
- Recoating against corrosion and chemical or biological attack
- Standard retubing to OEM specification
- Condition analysis – leak tests, fin-side and tube-side assessment, deposit and corrosion analysis; optional water testing and endoscopic inspection
- Spare parts, upgrades and replacements
Additional services
- Assembly/disassembly assistance, shipping and transport; installation supervision
- Spare parts and kits for Kelvion and other brands; leakage detectors for double tube systems
- Complete overhaul, repair or new production
- Renewal of corrosion protection and exterior painting
- Pressure testing with 3.1 certificate
- Modifications and replacements of Kelvion and non-Kelvion products; design change from single tube to compact systems
- Endoscopic tube-side and fin-side examination for pollution, corrosion and erosion
- Water and sample analysis; investigation of corrosion problems including destructive testing
More from Kelvion
- Kelvion Box Cooler
- Kelvion Charge Air Coolers
- Kelvion Exhaust Gas Recirculation Cooler
- Kelvion Charge Air Cooler Service
- Kelvion Heat Exchanger Modifications, Upgrades & Spare Parts
- Kelvion Service for Box Coolers
- Kelvion Service for Gasketed Plate Heat Exchangers
- Kelvion Service for Single Tube Heat Exchangers
- Kelvion Service for Welded Plate Heat Exchangers
Featured services
All services →Engineering & Design
Keel Cooler & Boxcooler Sizing and Engineering
Free application engineering from Fernstrum: cooler sizing, configuration, placement and installation advice for keel coolers and boxcoolers based on your engine, vessel and operating conditions — with data on file for all major engine makers.
Maintenance / Service Agreement
Accelleron Original Turbocharger Service and Spare Parts
OEM turbocharger service and original spare parts from Accelleron via 100+ service stations in 50+ countries, including authorized IHI RH..3/AT14 overhauls and servicing of other makes' turbochargers.
Training
H887 – Azipod Space Safety & Azipod VI Technical Blended Learning
ABB Marine Academy blended course (remote theory plus 5 days hands-on in Helsinki) on confined-space safety inside Azipod units and technical maintenance and troubleshooting of Azipod VI subsystems.
Similar services