Corvus Energy System / Package
Corvus Dolphin NxtGen ESS – Energy
High-energy variant of the Corvus Dolphin NxtGen marine battery system (lithium-ion NCA, 8.2 kWh modules), designed for lightweight hybrid and all-electric vessels with slow charge/discharge cycles.
Description
The Corvus Dolphin NxtGen ESS – Energy is the high-energy variant of Corvus Energy's Dolphin NxtGen marine energy storage system. It offers high energy density in a space-efficient, lightweight package for vessels with long, slow charge and discharge cycles, in both hybrid electric and all-electric applications.
Key features
- Low C-rate for slow charge and discharge, preserving battery life
- Low weight for improved vessel efficiency and reduced structural demands
- Rack-free design: modules stack in various configurations to use available battery room space
- Designed for voltages up to 1200 VDC; capacity and voltage scalable to vessel requirements
- Passive single-cell thermal runaway isolation, not dependent on active cooling
- Battery Management System (BMS) with remote monitoring
- Plug-and-play connections; enhanced EMI immunity for maritime environments
Technical data
- Chemistry: lithium-ion NCA
- Module size / increments: 8.2 kWh / 50 VDC
- C-rate peak (discharge/charge): 1.0CP / 1.0CP for 10 seconds
- C-rate continuous (discharge/charge): 0.4CP / 0.4CP
- Module dimensions: 666 (l) x 500 (w) x 100 (h) mm
- Module weight: 44.5 kg
- Single string range: 33–197 kWh / 130–1205 VDC
- Max gravimetric density (string): 172 Wh/kg (5.96 kg/kWh)
- Max volumetric density (string): 212.5 Wh/l
- Ingress protection: IP66 module, IP56 system
- Cooling: forced air
Safety
- Thermal runaway anti-propagation: passive, cell-level, DNV Pt6 Ch2 Option 1
- External fire suppression per SOLAS, class and Corvus recommendation
- Redundant fail-safe disconnect for over-temperature, over-voltage and under-voltage
- Integrated cell-level fusing for short-circuit protection
- Hard-wired emergency stop circuit; integrated ground fault detection
Approvals
- Type approval: BV, DNV, LR, RINA
- Cybersecurity type approval: DNV
Applications
Ferries, yachts, canal boats, tourist and sightseeing vessels.
More from Corvus Energy
Featured products
All products →Component
CENTA Flexible Coupling Service by Everllence PrimeServ
Authorized service for CENTA flexible couplings on four-stroke engines: periodic inspection, rubber element replacement, original spare kits, alignment checks and resilient mounting replacement.
Component
MXP
Accelleron MXP (Marine auXiliary Power) turbochargers for small-bore, medium-speed marine auxiliary engines from 600 kW to 2,000 kW, with HFO-capable turbine, VTG versions and self-service maintenance app.
Equipment
Stacked GRIDCOOLER® Keel Cooler
Two-tier (stacked or double-stacked) copper-nickel keel cooler that delivers more heat rejection in a smaller hull footprint — ideal for large engines and repowers.
Similar products