WhisperPower System / Package
DC PowerCube 48 VDC - 80 A
48 VDC heavy-duty battery charger/power supply, up to 4.3 kW, with dual input from shore power (90–264 VAC) and Genverter PM generator, plus 12 V/20 A slave output.
Description
The WhisperPower DC PowerCube 48 VDC – 80 A (part number 60202003) is a heavy-duty battery charger and power supply for large DC systems with big battery banks and significant DC consumption on marine and mobile/off-grid installations. It converts grid or generator power to ripple-free DC for lighting, electronics, pumps and other loads, and can operate as a power supply without batteries.
Key features
- Up to 3.5 kW from shore power and up to 4.3 kW from a Genverter© PM generator
- Dual input: AC grid supplemented by Genverter© input with adjustable load and rpm
- Adjustable AC input current (2–16 A) to match any shore supply
- 3+ step charging for AGM, gel, open/sealed lead-acid, traction and lithium-ion batteries; selectable via laptop or dipswitch
- 12 VDC / 20 A 3-step slave output
- WhisperConnect CAN-bus for central monitoring; standard analogue panel supplied
- Relay outputs for status and failure; inputs to disable grid or PM input
Technical data
- Nominal battery voltage: 48 VDC; output current 0–100 A (short-circuit protected)
- Recommended battery capacity: 200–1000 Ah
- Grid input: 90–264 VAC, 45–65 Hz; PM generator input: 80–300 VAC, 30–500 Hz
- Power factor: >0.85
- Protection: IP21; derating above 40 °C; overvoltage protection 68 VDC
- Dimensions: 268 × 316 × 575 mm; weight 26 kg
Specifications
| 60202003 | DC PowerCube 48 V - 80 A |
|---|---|
| Weight kg (lb.) | 26 (57.3) |
| Length x width x height, mm (in.) | 268 x 316 x 575 (10.6 x 12.4 x 22.6) |
| Nominal battery voltage | 48 VDC |
| Output current | 0 - 100 A (short circuit protected) |
| Output voltage | 43.0 / 57.0 VDC |
| Recommended battery capacity: | 200 to 1000 Ah |
| charge characteristic | 3+ step charge characteristic |
| Slave charger | 12 V - 20 A (3+ step charge characteristic) short circuit protected |
| Grid input voltage range | 90 - 264 VAC (45 - 65 Hz), (3 wire connection) |
| Grid input current | Adjustable, from 2 A to 16 A |
| PM generator input range | 80 - 300 VAC (30 - 500 Hz), (3 wire connection) |
| PM input current | Adjustable, from 2 A to 14.5 A |
| Power factor (cos phi) | > 0.85 |
| Power Factor Correction (PFC) | EN 61000-3-2 |
| Temperature compensation | -60 mV / °C |
| Supported battery types | Open and sealed lead acid: Gel / Traction / AGM / Spiral and Lithium-ion |
| Battery leakage current | <5 mA per battery |
| Charge voltages | Bulk, Absorption, Float |
| Charge voltage AGM / GEL at 25°C | 57.60 VDC, 57.00 VDC, 54.40 VDC |
| Charge voltage Traction at 25°C | 58.40 VDC, 57.80 VDC, 53.00 VDC |
| Charge voltage Open lead acid at 25°C | 57.00 VDC, 57.00 VDC, 53.00 VDC |
| Charge voltage Lithium ION at 25°C | 57.60 VDC, 54.40 VDC, 53.00 VDC |
| Return current from absorption to float | 6% of Imax |
| PowerCube status on/off | Digital output (relay, two-way contact) |
| Failure | Digital output (relay, two-way contact) |
| AC grid disabled | Digital input (potential free input, closed is disabled) |
| PM input disabled | Digital input (potential free input, closed is disabled) |
| Conformity | Directive EMC 2004/108/EC : EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022,EN 61000-3-2, 62040-2 Low voltage directive 2006/95/EC: EN 62040-1-1, EN 50091-2, EN 60950-1 |
| PM input isolation protection | Yes (open collector output 30 VDC, 100 mA) |
| Over temperature protection | Yes, derating above 40°C, shutdown at high temperatures. (with automatic restart after cooling down) |
| Overvoltage protection (manual restart needed) | 68 VDC +/- 0.5 VDC |
| Ingress Protection index | IP21 |
| Main battery connection | 2 x M10 studs |
| Slave battery connection | 1 x M5 stud |
| Earth grounding lug | 1 x M6 stud |
| AC grid input | 3 x M3 screw terminal block |
| PM grid input | 3 x M3 screw terminal block |
| Remote control panel | RJ12 |
| Battery temperature sensor | RJ12 |
| Whisper Connect CANbus | RJ45 |
| Voltage sense | Phoenix MSTB 2.5 / 2-ST-5.08 |
| Digital outputs | 6 x fastons (6.3 x 0.8) |
| Digital inputs | 4 x fastons (6.3 x 0.8) |
| Operating temperature range | -20 - 55°C (derating above 40°C) |
| Relative humidity in operation | up to 95% without condensation |
| Ventilation | Combined cooling (convection and forced (variable speed)) |
| Acoustic level | <52 dB |
| Warranty | 2 years |
| Accessories | Battery temperature sensor and remote control panel |
More from WhisperPower
- WhisperPower AC PowerCube 24 VDC – 14000 VA
- WhisperPower AC PowerCube 24 VDC – 7000 VA
- WhisperPower AGM battery 12 V - 100 Ah
- WhisperPower AGM Battery 12 V - 145 Ah
- WhisperPower AGM Battery 12 V - 200 Ah
- WhisperPower AGM Battery 12 V - 260 Ah
- WhisperPower AGM Battery 12 V - 55 Ah
- WhisperPower AGM Battery 12 V - 80 Ah
- WhisperPower Alternator 12 V
- WhisperPower Battery Equalizer 24 VDC
- WhisperPower DC PowerCube 24 VDC - 150 A
- WhisperPower Exhaust manifold kubota D722 Marine
Featured products
All products →Equipment
Konrad Stern Drive Product Line (500, 600 and 600B Series)
Konrad Marine 500, 600 and 600B series stern drives for working and high-speed boats: models 520, 540, 560, 620, 660, 680, 620B, 660B and 680B.
Equipment
Everllence B&W ME-GI Dual-Fuel Engine
Low-speed two-stroke dual-fuel engine running on LNG/methane or fuel oil using the diesel cycle, with methane slip of +/-0.2 g/kWh, for LNG carriers, container ships, tankers, PCTCs and bulk carriers.
Component
ACCX300-L
Accelleron ACCX300-L next-generation low-speed turbochargers for two-stroke main engines: compact, higher power density, modular platform design with flexible cartridge-based service and data-enabled services.
Similar products